Digi-Loop DSP Single Channel Loop Amplifier
Model: DL107 NET
- Network control - allows control and calibration of unit remotely with application software
- High continuous current 9.5 Arms (13.4 Apk) per output continuous
- LCD Screen with VU metering, easy one-button menu control
- DSP Audio Processing
- USB for firmware updates
Digi-Loop is definitely state-of-the-art – the first of its kind to maximize modern amplifier technology. Its network-control capability provides seamless, remote system set-up, operation and monitoring via laptop or tablet. DSP audio processing offers flexible, powerful software control of mixing, equalization, compression and more. Powerful Class D, pulse-width amplifiers maximize efficiency.
The Digi-Loops amplifier design offers either single or dual 9.5 A rms loop outputs for perimeter loop(s), single array(s), dual loop, or phased-array configuration. A 70-100 V input provides connection to a distributed speaker/paging system, ensuring announcements are heard by loop users.
System includes: (1) PLA DL107 NET Loop Amplifier, (1) WLC 004 Line Cord (US) & (1) IDP 009 ADA Wall Plaque (t-coil)
- Network control - allows control and calibration of unit remotely with application software
- High continuous current 9.5 Arms (13.4 Apk) per output continuous
- LCD Screen with VU metering, easy one-button menu control
- DSP Audio Processing
- USB for firmware updates
- Input mixing, parametric equalization, compression, metal compensation, high and low-pass filters, AGC and audio delay
- Power-save mode
- Adjustable output delay for multiple amps in large venues
- Fault warning and active protection against shorted or open circuits and overheating
- Loop fault relay output
- XLR and 3-position terminal block input configurable as microphone input or line-input, balanced or unbalanced.
- Standard 1 RU, 19" rackmount
- Magnetic signal couples directly to devices equipped with telecoils (T-coils) such as hearing aids, cochlear implants, or optional loop receivers.
- DL207 suitable for phased-array or dual-loop systems; DL107 suitable for perimeter loop or single array.
- Phased-array mode automatically produces 90° phase shift in slave loop output
- Meets IEC 60118-4 system performance requirements when integrated into a correctly designed and installed system.
- Test specification provided to IEC 62489-1 standard.
- Meets ADA / ADAAG guidelines.
- ROHS Compliant - Yes
- Warranty - Yes
- Spec Sheet available - Yes
- Operating Temperature (Maximum): 95 F
- Operating Temperature (Minimum): 32 F
- Certifications: CE, UL, ULC, FCC, Industry Canada, WEEE, CB scheme, RCM
- Depth: 10 in
- Height: 1.75 in
- Width: 19 in
- Product Weight: 9.20 lbs
- Warranty (Length/Type): 2 years
- General:
Dimensions: 1 RU Rackmount, 19” W x 1.75” H x 10” D. Chassis is 17” W.
Color: Case: Black, white and blue legends on front, white legends on back. LCD: Backlit Blue.
Fan cooling: Variable Speed, Temperature Controlled
Power supply: Internal, Universal 100-240 VAC, 50/60 Hz, 200 Watt. Fuse: 5 x 20 mm, 5 A, 250 V.; AC power plug is IEC 320-C14.
Heat output @ 120 VAC:
DL107 : Sleep State: 63 BTU/hr; Idle State: 71 BTU/hr; Driving one loop @ 9.5 A: 339 BTU/hr
DL207: Sleep State: 63 BTU/hr; Idle State: 84 BTU/hr; Driving two loops @ 9.5 A each: 638 BTU/hr
Ethernet:(1x) RJ-45; 10-100 MBps.
USB:(1x) standard-B. USB 1.1, 2.0 or 3.0 supported. - Coverage Area:
DL207 (dual output amplifier): 30,000 sq. ft. (2,786 sq. m.) (Perimeter Loops, 3:1 aspect ratio, both outputs driven); 18,000 sq. ft. (1,672 sq. m.) (Perimeter Loops, 1:1 aspect ratio, both outputs driven)
DL107 (single output amplifier): 15,000 sq. ft. (1,393 sq. m.) (Perimeter Loop, 3:1 aspect ratio); 9,000sq. ft. (836 sq. m.) (Perimeter Loop, 1:1 aspect ratio) - Inputs:
Dante input: On “D” models only. (1x) RJ-45;100 Mbps. Minimum latency: 2 ms. Audio sample rates supported: 44.1, 48 kHz. Resolution: 24 bits.
Line inputs: (1x) 3-position terminal block, 10 k ohm input impedance. Configurable/accepts -10 dBV, -4 dBu, +4 dBu, +8 dBu, balanced or unbalanced. Level adjustable 0 to -96 dB.
Mic/Line inputs: (1x) XLR 3-pin jack. Input impedance: 1.5 k ohm Mic, 10 k ohm Line. Configurable/Accepts: Mic, Line -10 dBV, Line +4 dBu, or Line +8 dBu, balanced or unbalanced. Phantom supply (24V).
70-100 V input: (1x) 2-position terminal block; high/speaker-level input (accepts 25 V, 70 V or 100 V) from distributed audio/paging systems. - Outputs:
Line outputs: (1x) 3-position terminal block; loop-through of Mic/Line Input 1 & Line Input 2, +4 dBu, Balanced or Unbalanced. The line outputs mirror the audio of the loop output.
Loop output(s): (1x) 2-position terminal block per output
Audio output delay: Adjustable from 0 to 165 msec
Headphone output: (1x) 1/4” stereo headphone jack, on front of unit. Monitored input or output selectable in menu.
Loop fault relay: (1x) 3-position terminal block providing NC, NO and Common. Contact rating: 2.0 A @ 30 VDC.
Loop output drive voltage: 16.1 Vrms (22.8 Vpk) continuous
Rated loop output current*: 9.5 Arms (13.4 Apk) per output
Loop resistance range: 0.5 ohm to 3.0 ohm (DC) - Audio:
Rated load*: 0.5 ohm DC with 135 µH inductance
Frequency response: 45 Hz to 9.0 kHz ± 2 dB (1 kHz ref.)
Rated loop THD*: <1 % at rated output current (1 kHz sine wave). - Other:
Front controls: Front LCD display menu access/adjustment via control button/dial.
Adjustable settings: Input mixing, parametric equalization, compression, metal loss compensation, high and low-pass filters, AGC and audio delay, output levels. See User Manual for adjustment range(s).
Internal calibration tools: Test tone generator with pink noise, loop current adjustment/matching. See User Manual for details.
Other features: Save/load configuration, loop test, priority input selection with adjustable threshold, loop fault relay, open/short and thermal protection. See User Manual for details.
Network control & firmware: Function control and calibration by DigiLoop PC App via ethernet (RJ-45). PC App requires Windows 7 or higher. Firmware updates through USB only.
Standards compliance: This product is designed to meet the IEC-60118-4 standard when correctly designed, installed and commissioned.
Test Specifications provided to the IEC 62489-1 standard.
Inland AV
422 Lucas Ave
CenterPort, MB R4B 0A7
Canada
(204) 786-6521
https://inlandav.ca/