Zum J-Box Sensor Integration Module
Model: ZUMMESH-JBOX-SIM
Part #: 6509506
- Zum™ wireless junction box-mounted sensor integration module
- Enables hard-wired occupancy and daylight sensors to be used with a Zum commercial lighting system
- Supports occupancy or vacancy sensing plus daylighting
- Compatible with Crestron GLS-ODT-C-NS and GLS-OIR-C-NS occupancy sensors
- Compatible with the Crestron GLS-LOL open-loop daylight sensor
Enables hard-wired occupancy and daylight sensors to be used with a Zum™ commercial lighting system.
The Zum™ J-Box Sensor Integration Module (ZUMMESH-JBOX-SIM) enables the use of hard-wired occupancy and daylight sensors with a Zum commercial lighting system. It is ideal for applications that may not be conducive to using battery-powered wireless sensors. It also enables the use of ultrasonic and dual-technology type sensors, as well as specialized sensors for hallway, high-bay, wet location, outdoor, and other applications.
One or more motion-detecting sensors can be connected to a single ZUMMESH-JBOX-SIM and configured to operate in either occupancy or vacancy-only mode. A single open-loop daylight sensor, photosensor, or photocell can also be connected to support daylight harvesting. The ZUMMESH-JBOX-SIM appears as a native Zum Mesh wireless device in the room, with all the same functionality and easy pair-and-play setup of a Zum wireless occupancy, vacancy, or daylight sensor.
The ZUMMESH-JBOX-SIM mounts directly to a 4-inch square junction box. It communicates wirelessly with one or more Zum dimmers, switches, and load controllers, allowing lights to turn on and off automatically based on room occupancy and vacancy, and dim automatically according to the amount of natural daylight in the room. It can also serve as a host for a Zum network bridge (ZUMMESH-NETBRIDGE) or Zum contact closure output (ZUMMESH-CCO).
- Zum™ wireless junction box-mounted sensor integration module
- Enables hard-wired occupancy and daylight sensors to be used with a Zum commercial lighting system
- Supports occupancy or vacancy sensing plus daylighting
- Compatible with Crestron GLS-ODT-C-NS and GLS-OIR-C-NS occupancy sensors
- Compatible with the Crestron GLS-LOL open-loop daylight sensor
- Compatible with STEINEL occupancy sensors and presence detectors
- Pair and play wireless integration with Zum dimmers, switches, and load controllers
- Zum Mesh peer-to-peer RF communications
- Easy setup and calibration with the press of a button
- Accommodates a Zum network bridge or Zum contact closure output device
- Knockout mount to a standard 4-inch square junction box
- 100-277 Volt AC line powered
- External terminal block low-voltage sensor connections
- Supplies 24 Volts DC to power the sensors
- UL® 2043 listed for installation in an environmental air handling space
- Systems Controlled - Lighting
- Operating Temperature (Maximum): 104 F
- Operating Temperature (Minimum): 32 F
- Certifications: UL, FCC
- Wireless: Yes
- AC Voltage (Maximum): 277 Volts
- AC Voltage (Minimum): 100 Volts
- Active Power: 1 Watt
- Current Draw: 0.25 Amps
- DC Voltage: 24 Volts
- Depth: 1.32 in
- Height: 3.25 in
- Width: 4.17 in
- Product Weight: 0.44 lbs
- Device Support:
•Occupancy/Vacancy Sensors
•Supports one or more 24 VDC powered motion detection type sensors wired in parallel
•Requires a maintained DC high logic signal >8 VDC, 24 VDC maximum when detecting occupancy (motion)
•Operates in either occupancy or vacancy mode depending on connection used (do not connect both)
•Compatible Crestron models: GLS-ODT-C-NS, GLS-OIR-C-NS, GLA-IR-QUATTRO-HD-COM1-24, GLA-IR-QUATTRO-HD-COM2-24, GLA-US-HALLWAY-COM1-24
•Daylight Sensors
•Supports a single 24 VDC powered open-loop photosensor (photocell) type sensor
•Requires a 0-10 VDC analog control signal to indicate the natural daylight level
•Compatible Crestron models: GLS-LOL - Wireless Communications:
•RF Transceiver: Zum Mesh and Zum Net 2-way RF, 2.4 GHz ISM Channels 15, 20, 25, or 26 (channel auto-selected), IEEE 802.15.4 compliant, AES-128 encryption
•Zum Mesh Range: 50ft (15 m) to nearest Zum Mesh peer-to-peer mesh network device(s), subject to site-specific conditions and individual device capabilities
•Zum Net Range: 50ft (15 m) to a Zum Net wireless gateway or nearest Zum Net mesh network device(s), requires the Zum Network Bridge (model ZUMMESH-NETBRIDGE), range between floors or ceilings is limited to one level, subject to site-specific conditions and individual device capabilities - Controls and Indicators:
•SETUP: (1) Pushbutton and (1) red LED, used for sensor calibration, test mode, room setup, and factory reset
•TEST: (1) Pushbutton and (1) green LED, used for installation test, room setup, and factory reset - Connections:
•Hot: (1) Class 1 flying lead, black, line power input
•Neutral: (1) Class 1 flying lead, white, neutral
•Ground: (1) Class 1 flying lead, green, ground
•24: (1) Stab terminal, 24 Volt DC sensor power output
•O: (1) Stab terminal, occupancy sensor input, detection threshold greater than 8 Volts DC, 24 Volts DC maximum
•V: (1) Stab terminal, vacancy sensor input, detection threshold greater than 8 Volts DC, 24 Volts DC maximum
•D: (1) Stab terminal, daylight sensor input, sensing range 0-10 Volts DC, 24 Volts DC maximum
•G: (1) Stab terminal, ground/common connection for sensors
•Expansion Port: Accessory port for optional Zum Network Bridge or Zum Contact Closure Output (model ZUMMESH-NETBRIDGE or ZUMMESH-CCO) - Construction:
•Housing: Plastic, white, UL 94 5VA flame rated
•Mounting: Mounts to the side of a 4-inch square junction box via a 1/2 inch conduit knockout, meets the requirements of UL 2043 for installation in an environmental air-handling (plenum) space